Freeware Software and Printed Surgical Guide Enable Intraradicular Post
Dental researchers and clinicians have demonstrated the single-case technical feasibility of performing guided fiber-post removal using a freeware implant-planning platform combined with a sleeveless, three-dimensionally printed surgical resin guide. Fiber pos
Illustrative imageDental researchers and clinicians have demonstrated the single-case technical feasibility of performing guided fiber-post removal using a freeware implant-planning platform combined with a sleeveless, three-dimensionally printed surgical resin guide. Fiber posts are commonly used in modern restorative dentistry to reconstruct endodontically treated teeth, but their clinical removal during nonsurgical retreatment remains technically demanding. Traditional post-removal techniques rely heavily on ultrasonic instrumentation, specialized extraction kits, or conventional rotary burs operated by freehand manipulation. Under routine practice, these conventional methods carry substantial risks of excessive or unnecessary loss of radicular dentin, root canal deviation, procedural complications, or significantly prolonged treatment times, especially when the post is deeply bonded or visually indistinct from adjacent restorative core composites and radicular dentin tissues.
The procedural difficulty associated with post removal is notably elevated in posterior teeth, where restricted oral access and limited direct visualization reduce operator control over long rotary instruments. Static guided endodontics has emerged as an approach to transfer a preplanned virtual drilling trajectory directly to the patient’s tooth, with prior clinical and experimental reports investigating guided post removal. While recent systematic and narrative reviews indicate potential advantages in pathway control and dentin conservation compared with freehand techniques, published literature emphasizes that clinical evidence remains limited. Available systems exhibit substantial technical heterogeneity and remain strictly dependent on radiographic image quality, digital registration accuracy, guide seating stability, and the mechanical coupling tolerances established between the cutting instrument and the printed guide.
Guided post removal and sleeveless guide concepts are established in digital dentistry, meaning that the technical challenge centers on transferring a planned intraradicular trajectory through a simple, accessible workflow without overstating the mechanical accuracy of the surgical guide. Previously documented techniques vary considerably in their selection of planning software, guide support mechanisms, sleeve configurations, drill selections, and physical methods for translating virtual planning into controlled drilling depths. Because of these distinct configurations, performance conclusions derived from one system cannot be automatically transferred to another. Tooth-supported guidance requires cone-beam computed tomography to visualize the internal root anatomy and post trajectory, whereas an intraoral scan captures external coronal tooth surfaces for guide support, requiring precise registration between both datasets.
A practical impediment in many clinical settings is the significant cost and proprietary barrier associated with commercial implant-planning platforms. To address accessibility, the authors integrated a freeware implant-planning environment into the treatment workflow. The procedure was implemented during routine dental care in a private dental practice located in Naples, Italy, involving a post-retained maxillary left first molar requiring nonsurgical endodontic retreatment due to a persistent periapical lesion predominantly located around the buccal roots. Although the existing fiber post was situated within the palatal root canal, its coronal trajectory and surrounding core composite obstructed access to the adjacent buccal canal orifices, necessitating complete post removal to permit thorough retreatment and subsequent post replacement.
Data collection began with a diagnostic preoperative periapical radiograph, followed by a clinically indicated cone-beam computed tomography scan acquired on a GALILEOS Comfort unit at eighty-five kilovolts and seven milliamperes using upper-jaw collimation measuring approximately fifteen by fifteen by eight and a half centimeters, reconstructed at an isotropic voxel size of zero point thirty millimeters. In accordance with indication-driven radiation safety principles, the authors noted that the smallest clinically justified field of view depicting the anatomical targets should be utilized. Concurrently, an intraoral surface scan of the maxillary dentition was captured and exported in standard tessellation language format to record the external dental contours used strictly for guide support rather than for visualizing internal pulp anatomy.
The volumetric radiographic dataset and optical surface scan were imported into the freeware implant-planning software Pylon, version 1.0, developed by TrueAbutment Incorporated. The radiographic volume was segmented using semi-automatic thresholding alongside manual multiplanar refinement to delineate the tooth, root boundaries, and fiber post. The intraoral scan mesh was registered to the radiographic volume through surface matching across unaffected occlusal and axial enamel surfaces of the guide-bearing teeth, deliberately avoiding metallic dental restorations and radiographic artifact areas. Alignment was monitored through the software’s color-coded deviation map and visually confirmed across multiplanar views, although a global numerical root-mean-square registration error was not recorded.
Within the software environment, a virtual implant was aligned along the long axis of the fiber post to serve solely as a geometric surrogate for trajectory planning. Multiplanar slices verified the relation of the planned path to visible post boundaries and external root walls. For this clinical case, the virtual planning specified a coronal diameter of one point eight millimeters and an overall drilling length of eight point zero millimeters, representing case-specific parameters. A tooth-supported surgical guide was designed over the scanned coronal surfaces of the treated molar and adjacent teeth extending at least one tooth mesially and distally, ensuring that physical guide support remained entirely on external coronal surfaces without extending into the pulp chamber.
The digital guide design incorporated an integral, sleeveless cylindrical guidance channel featuring a nominal computer-aided design internal diameter of two point five millimeters and a guidance height of five point zero millimeters to provide coronal directional control. Following digital modeling, the file was transferred to PreForm computer-aided manufacturing software, version 3.47.1, oriented at approximately thirty degrees to the build platform with supports applied strictly to non-intaglio surfaces. The surgical guide was fabricated on a Form 4B stereolithography printer using Surgical Guide Resin at a layer thickness of one hundred micrometers. Post-processing adhered to manufacturer specifications, involving a twenty-minute wash in ninety-nine percent isopropyl alcohol, air drying, thirty minutes of light post-curing at sixty degrees Celsius, and pre-vacuum steam sterilization at one hundred thirty-two degrees Celsius for four minutes.
Mechanical depth control was established using an ISO 018 long-shank round diamond bur mounted onto a specialized bur extender, designed so that the coronal extender stop physically contacted the flat superior surface of the printed guide at the targeted drilling depth. The extender stop functioned exclusively for vertical depth limitation and did not enter the resin channel or provide lateral guidance. A short segment of zero point zero seventy-six millimeter polytetrafluoroethylene tape was placed empirically at the stationary bur-extender coupling to reduce perceptible play, though this coupling was not placed inside the guide channel nor mechanically evaluated. Intraorally, the guide exhibited passive complete seating, stability, and lack of rocking across supporting teeth under alternating manual pressure.
Guided pilot drilling commenced at the center of the exposed post under magnification using a one-to-one handpiece operating at approximately ten thousand revolutions per minute with continuous water irrigation. Advancement proceeded in intermittent pecking passes of approximately one millimeter, withdrawing the instrument after each pass to irrigate the canal, recheck guide stability, and visually confirm central alignment. The pilot instrument was subsequently replaced by an extra-fine, one-millimeter narrow-flame diamond bur on the same extender to traverse the remaining post length. Residual loosened fiber fragments were conservatively cleared using a low-speed size two Gates-Glidden bur with light brushing movements, strictly following axial guided drilling rather than serving as the primary guidance tool.
Following complete post removal and chemical irrigation with sterile saline and sodium hypochlorite, conventional nonsurgical endodontic retreatment was completed, and a new Rebilda Post GT fiber post measuring one point thirty-five millimeters in diameter with a zero point two taper was adhesively luted before coronal restoration. The clinical outcome demonstrated passive seating, clinical stability, and centered entry through the fiber post without evidence of root perforation or canal deviation, successfully unblocking access to the buccal canal orifices. However, the evaluation was entirely descriptive; no postoperative three-dimensional volumetric assessment was executed to measure linear or angular trajectory deviation, residual dentin thickness, or volumetric dentin preservation, and postoperative two-dimensional radiography cannot quantify transfer accuracy.
The authors stressed that these observations demonstrate technical feasibility rather than validated mechanical accuracy, guide wear resistance, or clinical superiority over conventional extraction methods. Potential dimensional variations arising from resin printing, post-curing, intraoperative bur friction, and bur-channel clearance were not metrologically measured, and the empirical use of polytetrafluoroethylene tape represents a non-standardized adjustment. Furthermore, guided interventions carry procedural risks, including reported possibilities of root perforation during static guided endodontics, underscoring the necessity of continuous tactile and magnified visual control. The technique remains contraindicated when anatomical structures cannot be clearly resolved on radiographs, when scan registration is degraded by artifacts, when coronal support is insufficient, or when limited interarch space prevents instrument access.
Subject of Research: Guided fiber-post removal using freeware implant-planning software and a 3D-printed surgical guide
Article Title: Use of freeware implant-planning software and a 3D-printed surgical guide for guided fiber-post removal: A technical procedure
Article References: Ruggiero, G., Zarone, F., Ficuciello, F., Sorrentino, R., & Zara, E. (2026). Use of freeware implant-planning software and a 3D-printed surgical guide for guided fiber-post removal: A technical procedure. Digital Dentistry Journal, 4(1), Article 100128. https://doi.org/10.1016/j.ddj.2026.100128
Image Credits: AI Generated
DOI: 10.1016/j.ddj.2026.100128
Keywords: Fiber Post Removal, Guided Endodontics, Freeware Implant Software, Pylon Software, Surgical Guide, Stereolithography 3D Printing, Cone Beam Computed Tomography, Intraoral Scan, Nonsurgical Retreatment, Maxillary First Molar, Endodontic Guide Design, Sleeveless Guide Channel, Mechanical Depth Control, Bur Extender Stop, Radicular Dentin Preservation, Digital Dentistry Workflow, Technical Feasibility
News Source: Ophelia Keating. (November 24, 2026). Freeware Software and Printed Surgical Guide Enable Intraradicular Post Removal in Single Patient. Scienmag.