Co-Cooling Power Plants and Greenhouses Can Raise Desert Energy Efficiency

Integrating evaporative cooling towers from thermal power generation facilities directly with greenhouse agricultural operations can increase overall electricity generation efficiency by 2.4 percent in arid environments, according to a modeling study published

Illustrative imageIllustrative image

Integrating evaporative cooling towers from thermal power generation facilities directly with greenhouse agricultural operations can increase overall electricity generation efficiency by 2.4 percent in arid environments, according to a modeling study published in the Arabian Journal for Science and Engineering. The investigation, conducted by Julian David Hunt, Fateh Belaïd, Ryan Lefers, and Yoshihide Wada, evaluated a conceptual thermodynamic configuration designated as co-cooling thermal power. In conventional industrial layouts operating across hot and dry geographic zones, thermal power plants must reject significant quantities of low-temperature heat to maintain baseline thermodynamic efficiency, while commercial greenhouses require massive inputs of water and power to control interior microclimates. The authors demonstrated that instead of discharging warm, humid exhaust air directly into the ambient atmosphere as an unutilized byproduct, power generation facilities can direct this moisture-laden air stream into adjacent agricultural enclosures. When evaluated under the meteorological conditions characteristic of Riyadh, Saudi Arabia, the integrated approach simultaneously lowered net capital requirements and improved net electrical output across the combined water, energy, and food nexus.

The underlying operational challenge addressed by the research team stems from the severe climatic pressures imposed by arid environments, where high ambient dry bulb temperatures and acute freshwater scarcity impair both power generation and food production systems. In standard agricultural greenhouses operating in desert regions, growers encounter extreme difficulties in regulating internal temperature and humidity. To prevent crop failure, these facilities routinely deploy direct evaporative cooling pads that consume substantial volumes of freshwater and electrical energy. Simultaneously, thermal power stations—whether utilizing concentrated solar power, nuclear reactors, or conventional fuels—are governed by strict thermodynamic relationships where electrical generation efficiency depends directly on the condensation temperature of steam cycles. High desert temperatures elevate the temperature of available heat sinks, which substantially degrades plant performance during peak summer demand periods. While evaporative cooling towers present an effective means of achieving lower cold-reservoir temperatures due to low ambient humidity, the warm and saturated exhaust plume has historically been treated as industrial waste, creating an unexploited synergy between electricity producers and commercial growers.

To evaluate the viability and performance limits of combining these two systems, the researchers established a structured, three-stage methodological framework that systematically analyzed physical processes, thermodynamic states, and regional case conditions. Stage one characterized the operational baselines of independent power generation and greenhouse farming, mapping out the institutional and technical hurdles associated with coordinating electricity utilities and agricultural enterprises. These operational challenges encompass water availability, added parasitic pumping loads, corrosion from saline aerosols, control complexities in matching agricultural humidity with plant heat rejection, and layout constraints. Stage two evaluated the thermodynamic performance of co-cooling using detailed psychrometric chart analyses, calculations of water consumption rates, and assessments of the parasitic electrical loads required for seawater desalination and long-distance freshwater transportation.

For the baseline power generation and thermal cycle simulations, the study employed the International Atomic Energy Agency Desalination Economic Evaluation Program, widely known as the DEEP software package. The researchers modeled a representative large-scale steam turbine thermoelectric facility featuring a baseline thermal capacity of 1,800 megawatts thermal, a baseline electrical capacity of 600 megawatts electric, and an initial thermal efficiency of 33.3 percent. To isolate power generation and cooling metrics within software designed for cogeneration, the team incorporated a nominal reverse osmosis desalination unit with an intentionally minimal capacity of one cubic meter per day, drawing a negligible 0.14 kilowatts electric. In current business-as-usual frameworks located in water-stressed coastal territories, power plants frequently rely on once-through seawater cooling, rejecting heat directly into coastal waters where elevated summer sea temperatures of roughly 35 degrees Celsius force steam condensation temperatures up to 50 degrees Celsius, demanding 1,219 megawatts thermal of cooling to yield 473 megawatts electric, with 28 megawatts consumed on-site and 445 megawatts exported.

Under the proposed co-cooling arrangement, shifting cooling operations inland to evaporative towers allows the circulating water to reach much lower temperatures, such as 25 degrees Celsius, which reduces steam condensation temperatures down to 40 degrees Celsius. Within the DEEP framework, this drop in condensation temperature reduces total required cooling to 1,192 megawatts thermal while raising gross generation to 496 megawatts electric; after accounting for 30 megawatts electric in plant self-consumption, the exported power rises to 466 megawatts electric. The thermodynamic relationship governing this gain reflects the fundamental cycle efficiency equation, where efficiency equals one minus the ratio of cold-source temperature to hot-source temperature.

To quantify the simultaneous cooling delivered to agriculture, the researchers developed mathematical formulations linking latent heat dissipation, air mass flow, and enthalpy transformations across the cooling tower and greenhouse. Evaporative cooling load was modeled as the product of the water consumption rate and the latent heat of water evaporation, fixed at 2,265 kilojoules per kilogram. Psychrometric equations established the share of cooling allocated to the power plant and the greenhouse based on air enthalpy changes between the ambient inlet, the cooling tower exit, and the greenhouse exhaust. The model assumed an evaporative cooling efficiency of 80 percent, representative of commercial evaporative media in arid settings, and an evaporation share of 66 percent, with the remaining 34 percent allocated to blowdown drainage to prevent mineral scaling. Furthermore, the analysis accounted for parasitic energy loads: seawater reverse osmosis desalination was evaluated at 3.5 kilowatt-hours per cubic meter, or 12.6 megajoules per cubic meter, while water conveyance from the Arabian Gulf inland to Riyadh was modeled at 1.0 kilowatt-hour per cubic meter, or 6.3 megajoules per cubic meter.

The study evaluated these thermodynamic balances against long-term meteorological averages for Riyadh recorded between May and November, characterized by an average dry bulb temperature of 36 degrees Celsius, an average relative humidity of 15 percent, and a corresponding wet bulb temperature of 18 degrees Celsius. Under baseline psychrometric conditions where ambient air at 36 degrees Celsius enters the cooling tower and exits at 25 degrees Celsius and 90 percent relative humidity, the process delivers 20 kilojoules per kilogram of dry air for power plant cooling. When routed through the greenhouse and exhausted at 35 degrees Celsius and 50 percent relative humidity, the same air stream provides an additional 10 kilojoules per kilogram of dry air for agricultural cooling. Alternatively, configuring the cooling tower to discharge air at 22 degrees Celsius and 90 percent humidity lowers water temperatures for the steam cycle but shifts enthalpy shares, yielding 10 kilojoules per kilogram of dry air for power plant cooling and 13 kilojoules per kilogram of dry air for greenhouse cooling.

Comparing the integrated configuration against business-as-usual systems revealed critical trade-offs in water, pumping, and generation metrics. In the conventional separated paradigm, water consumption is confined strictly to cooling pads at the greenhouse site, requiring less total desalination and conveyance energy, where desalination accounts for 66 percent and pumping from the Arabian Gulf accounts for 33 percent of the water-related energy budget. The co-cooling plant demands higher gross volumes of desalinated water to support both thermal rejection and agricultural humidification, increasing conveyance pumping loads. However, psychrometric optimization across variable exhaust setpoints demonstrated that an optimum cooling tower exhaust air temperature of 23 degrees Celsius achieves an overall net efficiency increase of 2.4 percent after subtracting all parasitic energy demands for water treatment and transport. For an 1,800-megawatt thermal plant, this 2.4 percent improvement yields over 43 megawatts of net additional electricity delivered to the grid without burning extra fuel or generating incremental greenhouse gas emissions.

Beyond operational thermodynamic performance, the authors examined physical footprint ratios and capital expenditure considerations by modeling co-cooling alongside concentrated solar power infrastructure. Using geometric and thermal metrics derived from the 110-megawatt Crescent Dunes Solar Energy Project in Nevada—which spans 6.5 square kilometers with 1.2 square kilometers of mirrors—the authors evaluated land-use requirements. Assuming a 20 percent solar-to-electric conversion efficiency and agricultural cooling loads equivalent to internal solar gains, exhaust air at 25 degrees Celsius provides greenhouse cooling capacity equal to 1.28 times the generated thermal power, supporting a greenhouse area covering 5.7 percent of the solar plant area. At a 22-degree exhaust temperature, greenhouse cooling expands to 3.5 times generated thermal power, supporting an agricultural area reaching 15.5 percent of the solar field. Under broader operational assumptions, cooled agricultural space could span between 0.1 square kilometers at a 30-degree exhaust temperature up to 3.7 square kilometers at a 20-degree exhaust temperature, while eliminating separate greenhouse evaporative infrastructure and avoiding visible cooling tower vapor plumes that would otherwise obstruct solar mirrors.

The authors stressed that the publication presents an initial conceptual analysis rather than an empirical demonstration, noting significant practical hurdles that require verification in future pilot-scale research. Directing massive volumes of humid air between industrial cooling towers and agricultural greenhouses necessitates short-distance, large-diameter ducting to control pressure drops and prevent unwanted condensation. The auxiliary fan power needed to drive these airflows must be precisely quantified, as excessive parasitic fan loads could diminish the modeled 2.4 percent net efficiency gain. Furthermore, transporting warm, saturated air introduces biological and operational hazards, including the proliferation of microbial vectors such as Legionella and biofouling within ductwork, while sustained high humidity inside greenhouses may foster fungal plant pathogens if air circulation is not strictly managed. Because viability depends heavily on physical proximity, capital infrastructure, and complementary seasonal demands, the researchers concluded that localized field trials in arid zones will be essential to validate these thermodynamic and agricultural models under actual operational conditions.

Subject of Research: Thermal power plant and greenhouse agricultural co-cooling integration in arid climates

Article Title: Co-cooling in Thermal Power Plants for Advancing Water–Energy–Food Nexus in Arid Regions

Article References: Hunt, J. D., Belaïd, F., Lefers, R., & Wada, Y. (2026). Co-cooling in Thermal Power Plants for Advancing Water–Energy–Food Nexus in Arid Regions. Arabian Journal for Science and Engineering, 51(20), 22527-22540. https://doi.org/10.1007/s13369-026-11429-1

Image Credits: AI Generated

DOI: 10.1007/s13369-026-11429-1

Keywords: thermal power generation, greenhouse agriculture, co-cooling systems, evaporative cooling, arid climates, water-energy-food nexus, Riyadh case study, power plant efficiency, steam condensation, concentrated solar power, desalination energy, water pumping, psychrometric modeling, IAEA DEEP model, cooling towers, reverse osmosis, resource efficiency, agricultural cooling

News Source: Denise Maddox. (November 25, 2026). Co-Cooling Power Plants and Greenhouses Can Raise Desert Energy Efficiency by 2.4%. Scienmag.